基于对政府信息机房供电系统需求的深入了解和分析,在机房的基础设施方面,应注重UPS供电系统可靠性、安全性,而UPS的节能也成为重点考虑的项目;据调查显示,机房UPS的采购成本约占整个机房投入的5%左右,其电源消耗可能占机房总电耗的10%以上。降低以上两部分的费用也可以给数据中心带来非常好的经济效果。作为政府一直在大力倡导“节能减排”,并且以身作则,率先垂范。
通过对政府行业信息机房UPS供电方案的分析,从整体方案上结合某系列UPS的可靠性、冗余性、可扩展性、可维护性、安全性、现场工程安装可行性、安装环境的可利用性以及成本投资等实用方面进行论证,将用户的要求与UPS的产品特色进行有机的结合,才能取得较好的政府信息机房的UPS供电系统方案。
AMSTRON蓄电池AP12-17 系列说明及简介销售
AMSTRON蓄电池是被设计应用在浮动充电及循环充电使用,高重量能量密度结合了大小和形状的宽广选择,让电池在众多应用下有合理的选择,部分共同应用项目包括但不于常备或主要电源如下:
● 警报系统 (Alarm Systems)
● 有线电视 (Cable Television)
● 通信设备 (Communications Equipment)
● 控制设备 (Control Equipment)
● 计算机 (Computer)
● 电子收款机 (Electronic Cash Registers)
● 电子测试设备 (Electronic Test Equipment)
● 电动轮椅 (Electronic Powered Wheelchairs)
● 紧急照明系统 (Emergency Lighting Systems)
● 防火或保全系统 (Fire & ULTRAMAX Systems)
● 地理设备 (Geophysical Equipment)
● 海洋设备 (Marine Equipment)
● 医学设备 (Medical Equipment)
● 办公室微处理机 (Micro Processor Based Office Machines)
● 可携式电影和电视灯光 (Portable Cine & Video Lights)
● 电动工具 (Power Tools)
● 太阳能系统 (Solar Powered Systems)
● 电信系统 (Telecommunications Systems)
● 电视和录像机 (Television & Video Recorders)
● 玩具 (Toys)
● 不断电系统 (Uninterruptible Power Supplies)
● 自动贩卖机 (Vending Machines)
美国AMSTRON蓄电池使用注意事项
1.不要打破电池,电池电解液具有强烈的腐蚀性,对皮肤和衣物有腐蚀作用。
2.不要使电池短路,电池短路时,会导致机器损坏、电池发热、发生危险。
3.不要把电池投入火中,投入火中会引起电池爆炸。
4.不得捣毁电池,捣毁电池会使电池的安全结构受破坏。
5.避免电池正负极反接,正负极反接会使电池爆炸。
6.不要使电池过充电,并防止过大的电流放电。
7.不要破坏电池密封结构,电池密封结构受到破坏后,会引起电池漏液、火灾甚至爆炸。
8.不要将电池放置在密闭的容器或密闭的设备中进行充电,以免引起电池爆炸。
蓄电池的联接
容量不同、性能不同、生产厂家不同的蓄电池不可连接在一起使用。
实际容量相同的蓄电池或蓄电池组方可串联使用。
实际电压相同的蓄电池或蓄电池组方可并联使用。
蓄电池组连接和引出请用合适的导线。
连接和拆卸时务必切断电源,否则会触电甚至的危险。
正负极不得接反或短路,否则会使蓄电池严重受损,甚至发生爆炸。
连接部件应锁紧,防止产生火花;若接触面被氧化,可用苏打水清洗。 新安装的蓄电池在使用前应进行72小时浮充充电使蓄电池组内部电量均衡,方可进行测试或使用。
Amstron battery is designed and applied in floating charging andrecycling charging. High weight energy density combines wideselection of size and shape, so that the battery has a reasonablechoice in many applications. Some common application projectsinclude but are not limited to standing or main power supply asfollows:
● alarm systems
● cable television
● communications equipment
● control equipment
● computer
● electronic cash registers
● electronic test equipment
● electronic powered wheelchairs
● emergency lighting systems
● fire & Ultramax systems
● geographic equipment
● marine equipment
● medical equipment
● micro processor based office machines
● portable cine & Video lights
● 医学设备 (Medical Equipment
连接部件应锁紧,防止产生火花;若接触面被氧化,可用苏打水清洗。
新安装的蓄电池组在使用前应进行72小时浮充充电使蓄电池组内部电量均衡,方可进行测试或使用。
● power tools
● solar powered systems
● telecommunications systems
● Television & video recorders
● toys
● uninterruptible power supplies
● vending machines
Precautions for amstron battery in USA
1. Do not break the battery. The battery electrolyte has strongcorrosiveness, which can corrode the skin and clothes.
2. Do not short circuit the battery. If the battery is shortcircuited, it will cause damage to the machine, heat of the batteryand danger.
3. Do not put the battery into the fire, which will cause thebattery explosion.
4. Do not destroy the battery. Destroying the battery willdamage the safety structure of the battery.
6. Do not overcharge the battery and prevent excessivecurrent discharge.
7. Do not damage the sealing structure of the battery. If thesealing structure of the battery is damaged, it will cause leakage,fire or even explosion of the battery.
8. Do not place the battery in a closed container orequipment for charging, so as to avoid battery explosion.
Connection of batter
Batteries with different capacity, performance and manufacturershall not be used together.
batteries with the same actual capacity or battery packs canbe used in series.
the batteries or battery groups with the same actual voltagecan be used in parall
The positive and negative poles shall not be reversed or shortcircuited, otherwise the battery will be seriously damaged or evenexplode.
the connecting parts shall be locked to prevent sparks; ifthe contact surface is oxidized, it can be cleaned with sodawater.
the newly installed battery pack shall be floating chargedfor 72 hours before use to balance the internal power of thebattery pack before test or use.
为了使整个供电系统供电安全可靠,采用两级低压交流配电柜分级配电,机房空调、照明、消防、电梯等次重要负载设备建议直接接到一级低压交流配电柜上;关键的数据负载设备通过UPS接在二级低压配电柜;基于关键数据负载对供电的特殊要求,需要整个供电系统都必须采用具有高度模块冗余功能的并联冗余供电方案,采用两台某系列UPS并机实现“1+1”冗余功能。可靠性为单机UPS的5~7倍。整体方案具有管理先进、可靠度高及实用性强等特点。
(3)为了应对紧急事件的要求,某系列UPS提供了EPO紧急关机功能键,在UPS的正面板上有红色按键,可提供近端的快速关机,并提供网络远端紧急关机功能可供操作。只要此功能一经启动,UPS可快速关机,不必按照正常关机作业程序顺序关机。以便在紧急事故中节省时间,避免灾害的扩大。
(4)某型号UPS采用模块化设计,“N+X”冗余用户只需要购买相应的功率模块,即可实现“N+X”的故障冗余及升级扩容。
采用模块“N+X”冗余设计,电源阵列通过新的负载均分技术实现“N+X”冗余措施。负载均分意味着电源阵列中的所有模块并联运行并平均分担负载。“N+X”冗余意味着电源阵列比额定容量多配置X个模块,所有模块都将相互支持,能降低系统停机的风险。任何一个模块出现故障,都可自动脱离系统,确保系统正常运行,某模块化设计不仅块实现冗余,内部的辅助电源、PCB板也实现冗余。
真正实现各功能模块独立,任何一个功能模块损坏都互不干扰,大大提高系统的可靠度、可用性。
(5)某系列UPS采用先进DSP控制的IGBT整流专利技术,可提高输入功率因数(PF>0.99),降低总输入谐波电流(THDI<3%),如图2所示。达到洁净电力与节省能源的效益,成为“绿色电源”。
图2 传统UPS供电方案与某系列UPS供电方案输入功率因数和谐波电流的比较
给用户带来洁净的供电环境,节省了总体安装成本和运营成本,如降低上游配套变压器、线缆、空气开关、柴油发电机的容量(见表1)。
表1 某系列UPS与传统UPS在安装和运营成本上的比较
(6)某系列UPS采用专利的精简电路架构和散热风道设计,使功率模块具有高功率密度比——20kVA功率模块仅3U高度,在行业内可谓小巧精致的代表,体积小、重量轻,可节约安装空间,节省安装方面的投资,节约社会资源。
4 政府信息机房UPS供电方案的特点