传统UPS的客户,在规划时必须满足未来可预见的大负荷功率要求。比如,现在负载总容量只有20kVA,但因将来可能会增长到60kVA,客户在初始配置时通常都会直接采购功率为达到100kVA的UPS,以避免未来因升级困难而导致的可能容量不足。
HIFT(海福)UPS因采用模块化结构,可以在20kVA到480kVA的宽广范围内,以20kVA为单位来随时随需在线扩容,客户不再需要仅是为未来的可能性而提前投入大笔费用
HIFT(海福)UPS的这种灵活性,即允许配置容量贴近实际需求容量的能力,不仅降低了UPS的初始购置成本,更减少了配套设备(如空调)的配置与能耗支出,有效防止了基础设施超前超大规模设计导致的不必要开支。
AMSTRON蓄电池AP12-50 系列说明及简介销售
AMSTRON蓄电池是被设计应用在浮动充电及循环充电使用,高重量能量密度结合了大小和形状的宽广选择,让电池在众多应用下有合理的选择,部分共同应用项目包括但不于常备或主要电源如下:
● 警报系统 (Alarm Systems)
● 有线电视 (Cable Television)
● 通信设备 (Communications Equipment)
● 控制设备 (Control Equipment)
● 计算机 (Computer)
● 电子收款机 (Electronic Cash Registers)
● 电子测试设备 (Electronic Test Equipment)
● 电动轮椅 (Electronic Powered Wheelchairs)
● 紧急照明系统 (Emergency Lighting Systems)
● 防火或保全系统 (Fire & ULTRAMAX Systems)
● 地理设备 (Geophysical Equipment)
● 海洋设备 (Marine Equipment)
● 医学设备 (Medical Equipment)
● 办公室微处理机 (Micro Processor Based Office Machines)
● 可携式电影和电视灯光 (Portable Cine & Video Lights)
● 电动工具 (Power Tools)
● 太阳能系统 (Solar Powered Systems)
● 电信系统 (Telecommunications Systems)
● 电视和录像机 (Television & Video Recorders)
● 玩具 (Toys)
● 不断电系统 (Uninterruptible Power Supplies)
● 自动贩卖机 (Vending Machines)
美国AMSTRON蓄电池使用注意事项
1.不要打破电池,电池电解液具有强烈的腐蚀性,对皮肤和衣物有腐蚀作用。
2.不要使电池短路,电池短路时,会导致机器损坏、电池发热、发生危险。
3.不要把电池投入火中,投入火中会引起电池爆炸。
4.不得捣毁电池,捣毁电池会使电池的安全结构受破坏。
5.避免电池正负极反接,正负极反接会使电池爆炸。
6.不要使电池过充电,并防止过大的电流放电。
7.不要破坏电池密封结构,电池密封结构受到破坏后,会引起电池漏液、火灾甚至爆炸。
8.不要将电池放置在密闭的容器或密闭的设备中进行充电,以免引起电池爆炸。
蓄电池的联接
容量不同、性能不同、生产厂家不同的蓄电池不可连接在一起使用。
实际容量相同的蓄电池或蓄电池组方可串联使用。
实际电压相同的蓄电池或蓄电池组方可并联使用。
蓄电池组连接和引出请用合适的导线。
连接和拆卸时务必切断电源,否则会触电甚至的危险。
正负极不得接反或短路,否则会使蓄电池严重受损,甚至发生爆炸。
连接部件应锁紧,防止产生火花;若接触面被氧化,可用苏打水清洗。
新安装的蓄电池组在使用前应进行72小时浮充充电使蓄电池组内部电量均衡,方可进行测试或使用。
Amstron battery is designed and applied in floating charging andrecycling charging. High weight energy density combines wideselection of size and shape, so that the battery has a reasonablechoice in many applications. Some common application projectsinclude but are not limited to standing or main power supply asfollows:
● alarm systems
● cable television
● communications equipment
● control equipment
● computer
● electronic cash registers
● electronic test equipment
● electronic powered wheelchairs
● emergency lighting systems
● fire & Ultramax systems
● geographic equipment
● marine equipment
● medical equipment
● micro processor based office machines
● portable cine & Video lights
● power tools
● solar powered systems
● telecommunications systems
● Television & video recorders
● toys
● uninterruptible power supplies
● vending machines
Precautions for amstron battery in USA
1. Do not break the battery. The battery electrolyte has strongcorrosiveness, which can corrode the skin and clothes.
2. Do not short circuit the battery. If the battery is shortcircuited, it will cause damage to the machine, heat of the batteryand danger.
3. Do not put the battery into the fire, which will cause thebattery explosion.
4. Do not destroy the battery. Destroying the battery willdamage the safety structure of the battery.
6. Do not overcharge the battery and prevent excessivecurrent discharge.
7. Do not damage the sealing structure of the battery. If thesealing structure of the battery is damaged, it will cause leakage,fire or even explosion of the battery.
8. Do not place the battery in a closed container orequipment for charging, so as to avoid battery explosion.
Connection of batter
Batteries with different capacity, performance and manufacturershall not be used together.
batteries with the same actual capacity or battery packs canbe used in series.
the batteries or battery groups with the same actual voltagecan be used in parall
The positive and negative poles shall not be reversed or shortcircuited, otherwise the battery will be seriously damaged or evenexplode.
the connecting parts shall be locked to prevent sparks; ifthe contact surface is oxidized, it can be cleaned with sodawater.
the newly installed battery pack shall be floating chargedfor 72 hours before use to balance the internal power of thebattery pack before test or use.
MTTR近于0,模块化热插拔在线维修,大大缩短维修时间
随着科技的进步,系统可靠性越来越高,任何系统仍然都不是可靠的,客户的关注度逐渐从系统的高可靠性转向了高可用性,这时,MTTR就变得至为关键了。
无论UPS的可靠性有多高,业界公认,在整个供电系统中,薄弱的环节仍然是UPS。
客户的传统使用经验是哪怕遇到UPS的一个小零部件故障,系统也会转到旁路无法再逆变工作,从而让关键负载置于非常危险的无保护电源供电之下。
而更糟糕的,是当客户遇到问题时,并不能确定系统何时可以被修复。通常系统的修复时间,包括向厂商报修、厂商电话判断故障原因、工程师携备件赶赴现场、并在现场修复UPS。这里的每一环节,都有太多的不确定因素。比如,客户遇到问题时正逢晚上或节假日,报修困难;与厂商及时联络,如果工程师经验不足或是电话问询不易,则故障原因很可能判断不全甚至有误;客户所在地偏远和交通不便,赶赴现场完全不能控制在可满足时效内;后到达现场,现场查找原因与系统修复也需要相当时间,更别提没有拿对拿齐备品备件而导致系统无法被一次修复好了。而如果采用HIFT(海福)UPS则不同,以上种种问题迎刃而解。因为具有模块化结构,如果出现故障,只要移出问题模块就好,UPS系统仍然能够在线运行。新模块送到,现场热热接入系统,所费时间几近于0。(见下图)
时,因为系统修复采用的是简单易行的模块更换,现场维修的非标准化操作所可能导致的发生故障几率,被极其显着的降低了。
3.6.2 N+X冗余,提供系统高的可靠性。
「N+X冗余」通常指系统中N+X台UPS单机(或模块)并联运行,当大X台UPS单机(或模块)发生故障时,系统仍然能够逆变输出正常运行。
为了提高可靠性,传统UPS通常采用主从结构的1+1并联备份方案,这在一定程度上提高了可靠性,它不便于离线维护、扩容,对设备的利用不充分、缺乏灵活性。更重要的,是此时系统的冗余度仅为1。
而HIFT(海福)UPS的结构极具弹性,可实现N+1、N+2、N+3、N+4、N+5、或当并机时具有更高的N+X冗余。客户还可通过定购额外的模块,来增加HIFT的备用冗余能力。
即,同样的功率配置,HIFT(海福)UPS拥有更高的冗余度;而同样的冗余度,HIFT(海福)UPS拥有更经济的配置方案。(见下图)
通常UPS带载不会超过70%,在实际应用中,N+X冗余有高的系统可靠性。
冗余度越高,可靠性与可用性越高。
3.6.3 随需扩容,提供灵活的、经济的投资、配置策略
快速变化的业务要求企业机房和数据中心具备灵活性(Agility)。当更多的IT应用强调动态结构时,支撑这些应用的UPS供电系统是必须提前一步到位,还是可以根据需要灵活配置。